From cd43921285658372c0db8019684979edb74eaffd Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Rafa=C5=82=20Mi=C5=82ecki?= <zajec5@gmail.com>
Date: Wed, 11 Feb 2015 16:37:05 +0100
Subject: [PATCH soc] ARM: BCM5301X: Ignore another (BCM4709 specific) fault
code
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
Broadcom ARM devices seem to generate some fault once per boot. We
already have an ignoring handler for BCM4707/BCM4708, but BCM4709
generates different code.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
---
arch/arm/mach-bcm/bcm_5301x.c | 9 +++++----
1 file changed, 5 insertions(+), 4 deletions(-)
diff --git a/arch/arm/mach-bcm/bcm_5301x.c b/arch/arm/mach-bcm/bcm_5301x.c
index e9bcbdb..7aef927 100644
--- a/arch/arm/mach-bcm/bcm_5301x.c
+++ b/arch/arm/mach-bcm/bcm_5301x.c
@@ -18,15 +18,16 @@ static bool first_fault = true;
static int bcm5301x_abort_handler(unsigned long addr, unsigned int fsr,
struct pt_regs *regs)
{
- if (fsr == 0x1c06 && first_fault) {
+ if ((fsr == 0x1406 || fsr == 0x1c06) && first_fault) {
first_fault = false;
/*
- * These faults with code 0x1c06 happens for no good reason,
- * possibly left over from the CFE boot loader.
+ * These faults with codes 0x1406 (BCM4709) or 0x1c06 happens
+ * for no good reason, possibly left over from the CFE boot
+ * loader.
*/
pr_warn("External imprecise Data abort at addr=%#lx, fsr=%#x ignored.\n",
- addr, fsr);
+ addr, fsr);
/* Returning non-zero causes fault display and panic */
return 0;
--
1.8.4.5
|